R-value per inch by insulation type
Where sources differ, the chart shows the range. The last three columns are the thickness each material needs for common attic levels.
| Material | R per inch | For R-30 | For R-38 | For R-49 |
|---|---|---|---|---|
Fiberglass batts Rolls and batts for walls, floors and open attics. | 3.2–3.7 | 8.1–9.4 in | 10.3–11.9 in | 13.2–15.3 in |
Blown-in fiberglass Loose fill blown onto the attic floor. | 2.2–2.7 | 11.1–13.6 in | 14.1–17.3 in | 18.1–22.3 in |
Blown-in cellulose Recycled paper fiber, blown in; charts list settled thickness. | 3.6–3.7 | 8.1–8.3 in | 10.3–10.6 in | 13.2–13.6 in |
Mineral wool (rock wool) Batts sit at the high end of the range. | 3.1–4.3 | 7–9.7 in | 8.8–12.3 in | 11.4–15.8 in |
Open-cell spray foam Sprayed by a contractor; also seals air leaks. | 3.6–3.7 | 8.1–8.3 in | 10.3–10.6 in | 13.2–13.6 in |
Closed-cell spray foam Densest foam; highest R per inch. | 6–7.5 | 4–5 in | 5.1–6.3 in | 6.5–8.2 in |
Expanded polystyrene (EPS) board White bead board. | 3.8–4.5 | 6.7–7.9 in | 8.4–10 in | 10.9–12.9 in |
Extruded polystyrene (XPS) board Colored foam board; used below grade. | 5–5.5 | 5.5–6 in | 6.9–7.6 in | 8.9–9.8 in |
Polyisocyanurate (polyiso) board Foil-faced board. | 6–7.5 | 4–5 in | 5.1–6.3 in | 6.5–8.2 in |
Per-inch figures are for comparing materials. Loose fill is rated at the thickness and bag count on its coverage chart, so use the chart for the actual job.
Recommended R-values by climate zone
ENERGY STAR's recommendations for existing wood-framed homes, based on the 2021 International Energy Conservation Code. Not sure of your zone? Find it on the climate zone map on ENERGY STAR's R-value page.
| Zone | Uninsulated attic | Attic with 3–4 in: add | Floor |
|---|---|---|---|
| Zone 1 | R-30 | R-25 | R-13 |
| Zone 2 | R-49 | R-38 | R-13 |
| Zone 3 | R-49 | R-38 | R-19 |
| Zone 4A and 4B | R-60 | R-49 | R-19 |
| Zones 4C, 5 and 6 | R-60 | R-49 | R-30 |
| Zones 7 and 8 | R-60 | R-49 | R-38 |
Walls: whenever the siding comes off an uninsulated wood-frame wall, ENERGY STAR recommends blowing insulation into the empty cavities, then adding insulating sheathing under the new siding: R-5 in zone 3 and R-5 to R-10 in zones 4 through 8.
Attic insulation calculator
Measure the depth in a few spots between the joists and use a typical reading. Picking a zone fills in the ENERGY STAR attic target; you can type your own.
Result
Inches to add
16.7–21.5 in
- Existing insulation
- about R-12.8–14.8
- R-value to add
- R-45.2–47.2
- Volume to add
- 1,395–1,788 cu ft
Ranges come from the spread in R-value per inch. For bags, divide your attic area by the coverage per bag printed on the bag's chart for your target R-value; charts differ by brand.
Going with loose fill? The blown-in insulation calculator turns your attic area and target R-value into a bag count from the manufacturers' coverage charts.
Adding R-value the right way
- Layers add up. You don't need to remove old insulation that's dry and clean: two layers of R-19 batts make R-38. Lay unfaced batts across the old ones, or blow loose fill on top.
- Don't squash it. Fiber insulation works by trapping air. Compressing batts into a space that's too small lowers their R-value.
- Seal air leaks first. Gaps around pipes, wires, lights, and the attic hatch let warm air bypass the insulation. Caulk and foam them before you add more.
- Start with the attic. An open attic floor is usually the easiest place in the house to add a lot of R-value at once.
Better insulation lowers the heat your home loses, which can mean a smaller furnace. Size one with the furnace size calculator, and if the old one is due for replacement, price it with the HVAC replacement cost calculator.
Insulation R-value FAQ
What R-value do I need in my attic?
ENERGY STAR recommends R-30 for an uninsulated attic in zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 through 8. If the attic already has 3 to 4 inches, it recommends adding R-25 in zone 1, R-38 in zones 2 and 3, and R-49 in zones 4 through 8.
How many inches of insulation is R-38?
It depends on the material: about 14.1–17.3 in of blown-in fiberglass, 10.3–10.6 in of blown-in cellulose, or 10.3–11.9 in of fiberglass batts. For loose fill, go by the minimum thickness on the bag's chart, since that is what the R-value is rated at.
Is higher R-value always better?
Higher R-value always slows heat flow more, but each extra inch saves less than the one before it. Insulation fact sheets carry the FTC-required warning that if you buy too much insulation, it will cost you more than you'll save on fuel. Reaching the recommended level for your zone, and sealing air leaks first, is the usual target.
What is the R-value of a 2x4 wall vs. a 2x6 wall?
A 2x4 wall cavity is 3.5 inches deep and holds about R-13 to R-15 (R-13 fiberglass batts, R-15 mineral wool batts, or R-13 dense-packed cellulose). A 2x6 cavity is 5.5 inches and holds about R-21 to R-23 (dense-packed cellulose R-21, mineral wool batts R-23).
Sources (checked October 2026)
- ENERGY STAR, Recommended Home Insulation R-Values (based on 2021 IECC Table R402.1.3): zone table and wall sheathing guidance.
- PNNL Building America Solution Center, 2009–2021 IECC minimum insulation requirements: ceiling and floor values used to cross-check the zone table.
- US Department of Energy, Guide to Home Insulation (DOE/EE-0340): R-values of batts, spray foam, and foam board.
- University of Missouri Extension, Home Insulation Choices (EM104): R-value per inch table; compressed batts lose effectiveness.
- CertainTeed InsulSafe SP coverage chart: blown fiberglass thickness by R-value; FTC fact sheet wording.
- GreenFiber INS515LD attic card: cellulose settled thickness by R-value; dense-pack R-13 (2x4) and R-21 (2x6).
- ROCKWOOL Comfortbatt product table: R-15 at 3.5 in and R-23 at 5.5 in.
- NAIMA, Frequently Asked Questions About Insulation: R-values of layers add together.