Blown In Insulation Calculator

Enter your attic size, pick cellulose or fiberglass and a target R-value, and add any insulation that's already up there. You get the number of bags from real manufacturer coverage charts, how deep to blow it, and what the job costs done yourself or by a pro.

Your attic

Area: 1,000 sq ft. For an L-shaped attic, enter the total square feet as the length and 1 as the width.

Leave depth at 0 for a bare attic floor.

Bags you need

Cellulose bags for 1,000 sq ft

56–57 bags

Adding about R-49 on top of what's there.

Brand chartChart rowBagsBlow toSettles to
GreenFiber INS515LD30 lb bagR-495614.82 in13.34 in
Nu-Wool cellulose25 lb bagR-495715.01 in13.51 in
Hire a pro (installed)
$1,000–$4,000
DIY material
Enter a bag price

Bag counts come from each maker's coverage chart, rounded up to the next R-value row and the next whole bag. Bag sizes and coverage differ by brand: always check the chart printed on the bag you buy, and install both the bag count and the minimum thickness it lists.

Bags of blown-in insulation per 1,000 sq ft

Minimum bags per 1,000 square feet of open attic floor, straight from each manufacturer's chart. Bag weights differ, so compare brands by the chart, not by the bag.

Brand (bag)R-30R-38R-49R-60
Owens Corning AttiCat (fiberglass, 27.5 lb)14.6192531.5
CertainTeed InsulSafe SP (fiberglass, 31 lb)13.817.923.528.9
GreenFiber INS515LD (cellulose, 30 lb)30.840.95672.4
Nu-Wool cellulose (cellulose, 25 lb)33.24356.570

For any other area, multiply by your square feet and divide by 1,000, then round up. The charts are for estimating: the manufacturers note that job conditions, technique, and blower settings change actual coverage.

How deep to blow it

TargetFiberglassCellulose, as blownCellulose, settled
R-3010.75–11.5 in9.22–9.4 in8.3–8.46 in
R-3813.5–14.5 in11.6–11.76 in10.44–10.58 in
R-4917–18.25 in14.82–15.01 in13.34–13.51 in
R-6020.5–21.75 in17.99–18.27 in16.19–16.44 in

The R-value on the bag is only reached when you install both the bag count and the minimum thickness on its chart; one without the other means a lower R-value. Cellulose charts list a deeper installed depth because the fibers settle: GreenFiber's R-38 row, for example, is blown to 11.6 inches and rated at 10.44 inches settled. The fiberglass charts list the same number for both. Owens Corning's AttiCat instructions call for at least one depth ruler stapled up for every 300 square feet so you can see when you've reached the mark.

Cellulose vs. fiberglass

  • R-value per inch: cellulose about R-3.6–3.7, loose fiberglass about R-2.2–2.7. Fiberglass needs a deeper layer for the same R-value.
  • Bags: R-38 over 1,000 sq ft takes about 41–43 bags of cellulose against 18–19 of fiberglass. That's more trips up the ladder and more blower time with cellulose.
  • Settling: cellulose is blown deeper than its rated depth and settles; the fiberglass charts rate it at the depth you blow.

For R-value per inch of every common material and the recommended attic R-value for your climate zone, see the insulation R-value chart.

Blow it yourself or hire a pro?

Installed blown-in attic insulation typically costs about $1–$4 per square foot; Fixr puts a 1,500 sq ft attic at $1,750 to $5,500. Doing it yourself costs the bags plus the blower, which home centers that sell the bags usually rent; Fixr puts the rental at around $125 a day. Ask about rental terms when you buy. A pro is worth considering when air sealing, vent baffles, or removing old insulation are part of the job too.

Before you blow: vents, lights, and leaks

  • Keep soffit vents open. Loose fill pushed into the eaves can block the intake vents and let heat build up under the roof deck. ENERGY STAR's DIY guide says to put rafter vents (insulation baffles) between the rafters at the eaves first, plus a block such as rigid foam at the edge so blown insulation doesn't spill into the soffit.
  • Recessed lights and flues. Owens Corning says not to cover recessed light fixtures, or insulate within 3 inches of them, unless they are IC-rated, and to keep insulation out of the air spaces around metal flues, chimneys, and fireplaces.
  • Seal air leaks first. Gaps around pipes, wires, and the attic hatch let warm air bypass the insulation, and they are much easier to reach before the attic floor is covered.
  • Wet or moldy insulation. Owens Corning advises fixing the source of the water and removing contaminated insulation before you add more.

Blown-in insulation FAQ

How many bags of blown in insulation do I need?

For a bare 1,000 sq ft attic, R-38 takes about 41–43 bags of cellulose or 18–19 bags of fiberglass, and R-49 about 56–57 or 24–25. Multiply by your attic area in thousands of square feet, or use the calculator above, and subtract what's already there.

How many square feet does a bag of blown-in insulation cover?

It depends on the brand and the R-value. At R-38, the charts we checked give about 23–24 sq ft per bag of cellulose and 52–55 sq ft per bag of fiberglass. Fiberglass bags cover more area because the material is much lighter per square foot.

How deep should blown-in insulation be for R-38?

Fiberglass needs about 13.5–14.5 in for R-38. Cellulose is blown to about 11.6–11.76 in and settles to about 10.44–10.58 in. For R-49, plan on about 17–18.25 in of fiberglass or 13.34–13.51 in of settled cellulose.

Is cellulose or fiberglass better for blowing into an attic?

Cellulose gives more R-value per inch (about R-3.6–3.7 vs. R-2.2–2.7 for loose fiberglass), so the layer is thinner, but it takes more than twice as many bags and settles after it's blown. Fiberglass is lighter, doesn't settle on these charts, and needs fewer bags to carry into the attic. Both reach the same R-value when installed to the chart.

Is it cheaper to blow in insulation yourself?

Usually. Pros charge about $1–$4 per square foot installed, so a 1,000 sq ft attic runs about $1,000–$4,000. Doing it yourself costs the bags plus the blower, which home centers rent; Fixr puts rental at around $125 a day.

Can you put blown-in insulation over existing insulation?

Yes, if the old insulation is dry and clean. R-values of layers add, so measure what's there, subtract it from your target, and blow only the difference. Insulation that got wet and contaminated should be removed after the leak is fixed.

Sources (checked November 2026)

Related tools: insulation R-value chart, furnace size calculator, HVAC replacement cost calculator.